Frequency-dependent leakage inductance is often observed. The high-frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high-frequency leakage inductance and proposes an accurate prediction methodology. High-frequency leakage inductances in several interleaved winding configurations are also discussed. Interleaved winding configurations actually give a smaller degree of reduction of leakage induction at high frequency. Finite-element analysis simulation and measurement validate the models.
No takes yet. Share an insight, caveat, or question.
Ouyang et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: