Answers are grounded in this paper and cite their sources.
The removal of N2(A 3Σu+, v′=0,1) by O2 has been studied in a room temperature discharge-flow apparatus by monitoring the temporal decay of the 0,6 and 1,10 bands of the Vegard–Kaplan system. Rate constants for the reaction with O2 are (2.3±0.4) and (4.1±0.7)×10−12 cm3 molecule−1 s−1 for v′=0 and 1, respectively. The rate constant measured for v′=0 is about 35% lower than commonly accepted values for the rate constant for quenching N2(A) by O2. This discrepancy is shown to result from the fact that most other studies used a tracer to monitor the N2(A) number density. The rate of decay of the tracer reflects both the decay of the v′=0 and v′=1 levels of N2(A) and its value is midway between the decay rates of the individual vibrational levels.
No takes yet. Share an insight, caveat, or question.
Piper et al. (1981) studied this question.