Why the study?
Transient ischaemic dilatation has diagnostic and prognostic value in obstructive CAD, but its clinical significance in non-obstructive CAD remains unknown.
Does abnormal transient ischemic dilatation (TID ≥ 1.03) on 13N-ammonia PET MPI predict MACE in patients with non-obstructive CAD?
Does abnormal transient ischemic dilatation (TID ≥ 1.03) on 13N-ammonia PET MPI predict MACE in patients with non-obstructive CAD?
In patients with non-obstructive CAD, an abnormal transient ischemic dilatation (≥ 1.03) on 13N-ammonia PET MPI is an independent predictor of major adverse cardiac events.
Answers are grounded in this paper and cite their sources.
TID ≥1.03 on 13N-ammonia PET may flag higher MACE risk in non-obstructive CAD; extends TID data but needs prospective validation.
Objective Transient ischaemic dilatation (TID) had incremental diagnostic and prognostic value in obstructive coronary artery disease (CAD), but its clinical significance in patients with non-obstructive CAD remains unknown. We aimed to explore the prognostic value of TID in patients with non-obstructive CAD by 13 N-ammonia PET imaging. Methods We retrospectively studied 131 consecutive patients with non-obstructive CAD undergoing one-day rest-stress 13 N-ammonia PET myocardial perfusion imaging (MPI). TID was automatically generated using CardIQ Physio software. The receiver operative characteristic (ROC) curve was used to determine the optimal threshold of TID. The follow-up outcome was major adverse cardiac events (MACE), a composite of re-hospitalization for heart failure or unstable angina, late revascularization, non-fatal myocardial infarction, and cardiac death. Cardiac event-free survivals for normal and abnormal TID were compared using Kaplan–Meier plots and log-rank tests. Results During a median follow-up of 42.08 ± 17.67 months, 22 (16.7%) patients occurred MACE. The optimal cut-off value of TID was 1.03 based on MACE. Our preliminary outcome analysis suggests that TID-abnormal subjects had a lower overall survival probability. Furthermore, our multivariate analysis reveals abnormal TID was the only independent predictor for MACE in non-obstructive CAD. In the subgroup analysis, an abnormal TID was an independent predictor for MACE in patients with abnormal perfusion patterns. Conclusion Among patients with non-obstructive CAD, PET-derived TID ≥ 1.03 may identify those with a high risk of subsequent MACE independently. It was also an independent risk factor for poor prognosis in patients with abnormal perfusion. Graphical abstract CAD coronary artery disease, PET positron emission tomography, MPI myocardial perfusion imaging, TID transient ischaemic dilatation, MACE major adverse cardiac events, ROC receiver operative characteristic.
No takes yet. Share an insight, caveat, or question.
Jia et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: