Answers are grounded in this paper and cite their sources.
A polymerase chain reaction (PCR) was developed for Chlamydia trachomatis in which a 380 base pair DNA fragment was amplified. Amplification occurred with the DNA from the 15 serovars but not with that from other Chlamydia spp or with DNA from a variety of other organisms. Chlamydial DNA (10(-16) g) could be detected and the PCR seemed to be able to detect single organisms. Urethral swabs were obtained from 37 men with acute non-gonococcal urethritis (NGU), 18 (49%) of whom were positive for C trachomatis by MicroTrak. As a result of clinical re-examinations 65 urethral swabs were available for analysis by the PCR. In comparison with MicroTrak, PCR had a sensitivity of 95%, a specificity of 94%, a positive predictive value of 86% and a negative predictive value of 98%. The PCR was apparently less sensitive (82%) in tests on urine samples. Overall, however, values of sensitivity and specificity of the PCR compared favourably with those of MicroTrak. The PCR for C trachomatis is likely to be a valuable technique for research, but problems of DNA contamination suggest that it should not be recommended for routine diagnosis.
No takes yet. Share an insight, caveat, or question.
Palmer et al. (1991) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: