Highlights the risk of delayed presentation of treatment failure and thrombotic complications when using low molecular weight heparin for bridging in patients with mechanical mitral valves.
Answers are grounded in this paper and cite their sources.
Possible delayed thrombotic events after LMWH bridging warrant vigilance in mechanical mitral valve patients; leaves open optimal strategies for prospective study.
We describe a patient who developed right basal ganglion stroke and partial obstruction of St. Jude mitral valve prosthesis as a result of treatment failure with enoxaparin. The patient did not develop the embolic complication from the thrombosis until almost 4 months after the bridging sequence with low molecular weight heparin. The patient underwent thrombectomy of the mitral valve. At least 16 similar cases with mechanical valve prostheses and treatment failure of low molecular weight heparin have been reported.
No takes yet. Share an insight, caveat, or question.
Stamou et al. (2007) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: