Answers are grounded in this paper and cite their sources.
This paper presents a design methodology and analysis of electronic ballast employing the self-oscillating-command circuit. The self-oscillating electronic ballast is represented as a relay control system in order to determine its parameters using the describing-function method and an extended Nyquist stability criterion. Simulation and experimental results of the electronic ballast supplying a 40-W fluorescent lamp are presented in order to confirm the feasibility of the performed design methodology.
No takes yet. Share an insight, caveat, or question.
Seidel et al. (2007) studied this question.