Answers are grounded in this paper and cite their sources.
The functionalization of microelectrodes has been carried out by oxidative polymerization of a biotinyl pyrrole monomer in acetonitrile. The resulting biotinylated polymer was used for the simple and reagentless anchoring of avidin and biotinylated enzymes via avidin-biotin bridges. Thus, the immobilization of five layers of glucose oxidase was performed on various platinum electrodes (surfaces: 0.165 and 0.448 mm2). The amperometric response of the microbiosensors to glucose was recorded at 0.6 V vs Ag/AgCl and the analytical performances (sensitivity and I max) were proportional to the microelectrode surface. In addition, the immobilization of four and seven layers of polyphenol oxidase on carbon fiber microelectrodes (diameter 8 μm) has led to amperometric biosensors for catechol exhibiting analytical characteristics proportional to the number of enzyme layers. Moreover, these two kinds of microbiosensor present apparent K M values similar to those determined for the free enzymes in bulk solution.
No takes yet. Share an insight, caveat, or question.
Cosnier et al. (2001) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: