Answers are grounded in this paper and cite their sources.
Long-term durability is becoming increasingly relevant for capacitive deionization (CDI) as the technology emerges on the commercial scale. Short-term deionization studies have suggested that Faradaic leakages could be a major factor in electrode degradation, but the long-term effects are still unclear. In this study, we probe the degradation process of the desalination efficiency in commercial CDI modules for up to 52 days of non-stop operation. This corresponds to a little more than 100 m3 of water treated, and the lifetime production volume of the modules is estimated between 150,000–250,000 l of purified water. Surprisingly, the results demonstrate that the absolute long-term loss is largely linear with the cumulative charge leakage. This suggests short-term leakage currents could reasonably predict long-term degradation. Interestingly, the absolute loss mechanisms mean devices with higher total capacitance are more degradation resistant. Finally, shortening cycle times and other methods of reducing leakage would lead to a proportionally longer lifetime. Notably, the first 2 min of the 10 min operation retained 50 % of the performance with only 10 % of the leakage (10-fold reduction). In conclusion, the work provides a method for understanding, predicting, and reducing degradation in long-term operations with commercial CDI modules.
No takes yet. Share an insight, caveat, or question.
Nordstrand et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: