T his study was undertaken to determine the effect of gingival inflammation and probing pressure on probe tip placement in relation to the base of the gingival crevice and the most coronal connective tissue attachment fibers. Nine young male beagle dogs were divided into three groups as determined by clinical status of the gingiva following implementation of a protocol designed to produce gingival health and disease. An electromechanical device was used to advance 0.6 mm diameter probes into the facial gingival crevices of selected teeth and to obtain force‐displacement curves. The instrument stopped the probe at pressures of either 80, 160, 320, 640, 1280, or 2560 kPa which were randomly allocated to 12 test teeth in each dog. After the probe came to rest, it was attached to the tooth. When all 12 probes were attached, the animal was sacrificed. Blocks consisting of gingiva, probe, and tooth were processed to obtain two buccolingual sections, one containing the probe and the other immediately adjacent to it. Clinical and histometric measurements were performed and the data evaluated. Although three groups of animals were discernable by clinical criteria, only two groups, health and disease, could be formulated based on the degree of histologic inflammation. The histologic grouping was used in data analysis. Histometric distances from the cemento‐enamel junction to the base of the crevice (cJ), to most coronal connective tissue attachment (cC) and to the probe tip (cP) all increased with change from health to disease. However, changes in health/disease did not influence differences between distances (cP‐cJ,cP‐cC). It was therefore concluded that inflammation was not a factor in probe tip position relative either to the base of the crevice or to the most coronal connective tissue attachment. However, pressure was a significant factor. Therefore, the pressures at which cP = cJ and cP = cC were computed. Placement of a probe at the base of the crevice required an estimated 474 kPa or a force of. 17 N using a probe of 0.6 mm in diameter. The pressure required to place the probe at the most coronal connective tissue attachment was estimated at 1927 kPa or a force of.69 N using a probe of similar diameter. ( J Periodontol 1989;60:498– 505.)
No takes yet. Share an insight, caveat, or question.
Garnick et al. (1989) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: