In real-world practice in Japan, approximately 30% of atrial fibrillation cases are estimated to be overlooked by an initial Holter ECG, highlighting a significant clinical challenge in early detection.
Answers are grounded in this paper and cite their sources.
May miss substantial AF with initial Holter; leaves open optimal monitoring strategies pending prospective validation.
Holter whose AF was detected for the first time at the second or subsequent Holter, we estimated the number of diagnosis with AF and overlooked AF by initial Holter. We conducted sensitivity analyses changing the definition of AF, the potential detection period, and the washout period (a period required to avoid including patients who have already been diagnosed with AF or who have already undergone several Holters) to confirm the validity of the base scenario.Among patients for analysis, 88.4% had only one Holter. The percentage of AF diagnosis by initial Holter was 7.6%. The percentage of AF overlooked by initial Holter was estimated to be 31.4% and this value did not change much by sensitivity analyses.It was estimated that approximately 30% of AF patients were overlooked by initial Holter, and reducing the overlooked rate will be a clinical challenge.
No takes yet. Share an insight, caveat, or question.
Irie et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: