Answers are grounded in this paper and cite their sources.
The thick-target method for the measurement of the ratio of total to scattering cross section for low-energy neutrons as a function of energy has been extended to include semi-thick targets. A family of calibration curves has been developed by means of which the measured scattered count may be interpreted in terms of (σₛσₜ) in the range 0-1.The 5.19-ev and 16.6-ev levels of silver have been investigated by this method. The data agree very well with a Breit-Wigner shape over a wide range centered at the resonance, although slight deviations can be noted at distance >~10Γ away from resonance. The scattering measurements yield three independent ratios between various groups of the Breit-Wigner parameters. These ratios may be used together with transmission data to calculate the parameters. The results obtained for silver are for the 5.19-ev level: Γ=0.128 ev, Γₙ=0.0155 ev, σₜ₀=22200 barns, RJ=1=0.66 barn^; for the 16.6-ev level: Γ=0.110 ev, Γₙ=0.039 ev, σₜ₀=7300 barns, RJ=0=1.10 barn^; σₚ(normalelement)=5.90 barns.
No takes yet. Share an insight, caveat, or question.
Sheer et al. (1955) studied this question.