Why the study?
Sleep apnea is a common, underdiagnosed condition linked to increased cardiovascular risk, but whether wearable watch photoplethysmography pulse wave data can detect it was unclear.
Does PPG pulse wave data from a wearable watch device analyzed by the ACAT algorithm accurately detect moderate-to-severe sleep apnea compared to standard polysomnography?
Does PPG pulse wave data from a wearable watch device analyzed by the ACAT algorithm accurately detect moderate-to-severe sleep apnea compared to standard polysomnography?
Continuous PPG pulse wave data from a wearable watch device, when analyzed by the ACAT algorithm, can accurately screen for moderate-to-severe sleep apnea, offering a potential cost-effective tool for large-scale screening.
Answers are grounded in this paper and cite their sources.
Wearable PPG may enable daily-life sleep apnea screening; leaves open diagnostic accuracy versus PSG in larger cohorts.
The spread of wearable watch devices with photoplethysmography (PPG) sensors has made it possible to use continuous pulse wave data during daily life. We examined if PPG pulse wave data can be used to detect sleep apnea, a common but underdiagnosed health problem associated with impaired quality of life and increased cardiovascular risk. In 41 patients undergoing diagnostic polysomnography (PSG) for sleep apnea, PPG was recorded simultaneously with a wearable watch device. The pulse interval data were analyzed by an automated algorithm called auto-correlated wave detection with adaptive threshold (ACAT) which was developed for electrocardiogram (ECG) to detect the cyclic variation of heart rate (CVHR), a characteristic heart rate pattern accompanying sleep apnea episodes. The median (IQR) apnea-hypopnea index (AHI) was 17.2 (4.4-28.4) and 22 (54%) subjects had AHI ≥15. The hourly frequency of CVHR (Fcv) detected by the ACAT algorithm closely correlated with AHI ( r = 0.81), while none of the time-domain, frequency-domain, or non-linear indices of pulse interval variability showed significant correlation. The Fcv was greater in subjects with AHI ≥15 (19.6 ± 12.3 /h) than in those with AHI <15 (6.4 ± 4.6 /h), and was able to discriminate them with 82% sensitivity, 89% specificity, and 85% accuracy. The classification performance was comparable to that obtained when the ACAT algorithm was applied to ECG R-R intervals during the PSG. The analysis of wearable watch PPG by the ACAT algorithm could be used for the quantitative screening of sleep apnea.