In a smart house connected to a smart grid via advanced metering infrastructure, a nonintrusive load monitor (NILM) that identifies individual appliances by disaggregating composite electric load signal from the minimal number of sensors installed at the main distribution board in the field can be regarded as a part of a home/building energy management system. This type of load monitoring technique, not only for domestic but also for industrial applications, is relevant to electricity energy management and conservation issues. In this paper, an improved time-frequency analysis-based NILM composed of three system components, including data acquisition, transient feature extraction, and load identification, is proposed. The improved NILM proposed in this paper incorporates a multiresolution S-transform-based transient feature extraction scheme with a modified 0-1 multidimensional knapsack algorithm-based load identification method to identify individual household appliances that may either be energized simultaneously or be identified under similar real power consumption. For the load identification process, an ant colony optimization algorithm is employed to perform combinatorial search that is formulated as a modified 0-1 multidimensional knapsack problem. As shown from the experimental results, the improved NILM strategy proposed in this paper is confirmed to be feasible.