Why the study?
Does routine recording of lead III during deep inspiration differentiate between abnormal Q waves indicating diaphragmatic infarction and benign Q waves?
Does routine recording of lead III during deep inspiration differentiate between abnormal Q waves indicating diaphragmatic infarction and benign Q waves?
Answers are grounded in this paper and cite their sources.
Recording lead III during deep inspiration may not reliably differentiate benign Q waves from those caused by diaphragmatic myocardial infarction.
To the Editor.— In a LETTER TO THE EDITOR (224:1533, 1973) entitled " `Lead Thirteen' Electrocardiography," Dr. Sanford Lewis makes a plea for the routine recording of lead III during deep inspiration to differentiate between abnormal Q waves indicating diaphragmatic infarction and benign Q waves. Q waves persisting during inspiration are regarded as due to diaphragmatic infarction. We disagree with this recommendation. In our experience this maneuver has not been helpful in distinguishing abnormal Q waves due to diaphragmatic myocardial infarction from benign Q waves. A Q wave is considered abnormal if it is 0.04 seconds or more in duration and at least 25% of the QRS voltage (amplitude) It is true that in many individuals a Q wave in lead III may disappear or become insignificant on deep inspiration. This, however, does not always establish the benign nature of the Q wave, since a marked number of patients with well-established
No takes yet. Share an insight, caveat, or question.
U. R. Shettigar (1973) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: