A dissolution test for milnacipran hydrochloride capsules was developed and validated according to international guidelines. After selection of the best conditions, the method was validated using USP Apparatus 1 (baskets), 50-rpm rotation speed, 900 mL of 0.01 N HCl, and test time of 60 min. The drug released was determined by both LC-UV (PDA) and UV-D 2 methods. The kinetic parameters of drug release (mathematical models, t 80% , and dissolution efficiency) were investigated, and the stability of the dosage form was evaluated by analyzing changes in the dissolution rate of milnacipran hydrochloride capsules during storage at 40 C and 75% RH for different periods.