For application in high-power transmission cables, multifilamentary 2223 BPSCCO/Ag tapes have been prepared using the powder-in-tube (PIT) process. Critical current densities at 77 K of 33 kA/cm/sup 2/ in short samples and 22 kA/cm/sup 2/ over 400 m have been achieved. Machine stranded flexible cable conductors have been made with a length up to 10.5 m. The electrical performance has been evaluated at 77 K both under DC and AC conditions, yielding a current capacity up to 1420 A and purely hysteretic AC losses. Tests of the mechanical stability under bending conditions and repeated thermal cycling showed no serious degradation of the electrical performance.
No takes yet. Share an insight, caveat, or question.
Leghissa et al. (1997) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: