Key result
PAD-wedge decoupling is associated with ~9% higher 1-year death and HF readmission after LVAD.
Cohort (n=63)
No
Background: A cohort of heart failure (HF) patients receiving left ventricular assist devices (LVADs) has decoupling of their diastolic pulmonary artery pressure and pulmonary capillary wedge pressure. However, the clinical implications of this decoupling remain unclear. Methods and Results: In this prospective study, patients with LVADs underwent routine invasive hemodynamic ramp testing with right heart catheterization, during which LVAD speeds were adjusted. Inappropriate decoupling was defined as a >5 mm Hg difference between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure. The primary outcomes of survival and heart failure readmission rates after ramp testing were assessed. Among 63 LVAD patients (60±12 years old and 25 female [40%]), 27 patients (43%) had inappropriate decoupling at their baseline speed. After adjustment of their rotation speed during ramp testing, 30 patients (48%) had inappropriate decoupling. Uni/multivariable Cox analyses demonstrated that decoupling was the only significant predictor for the composite end point of death and heart failure readmission during the 1 year following the ramp study (total of 18 events; hazards ratio, 1.09; 95% confidence interval, 1.04–1.24; P <0.05). Furthermore, normalization of decoupling (n=8) during ramp testing was significantly associated with higher 1-year heart failure readmission–free survival rate compared with the non-normalized group (n=19, 100% versus 53%; P =0.035). Conclusions: The presence of inappropriate decoupling was associated with worse outcomes in patients with LVADs. Prospective, large-scale multicenter studies to validate the result are warranted.
No takes yet. Share an insight, caveat, or question.
Imamura et al. (2017) conducted a cohort in Heart failure with continuous flow left ventricular assist device (LVAD) (n=63). Inappropriate decoupling between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure (>5 mm Hg difference) vs. No inappropriate decoupling (or normalization of decoupling during ramp testing) was evaluated on Composite of death and heart failure readmission at 1 year (HR 1.09, 95% CI 1.04-1.24, p=<0.05). Decoupling between diastolic pulmonary artery and wedge pressures predicted 1-year death and HF readmission in LVAD patients (HR 1.09; 95% CI 1.04-1.24; P<0.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: