June 7, 2007European Journal of Cardio-Thoracic SurgeryOpen Access

The impact of intraoperative transit time flow measurement on the results of on-pump coronary surgery

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Does intraoperative transit time flow measurement improve surgical outcomes in patients undergoing on-pump coronary artery bypass grafting?

Population

200 patients undergoing on-pump isolated coronary artery bypass grafting via median sternotomy performed by…

Comparison

Intraoperative transit time flow measurement for… vs No TTFM.

Design

Cohort

Follow-up

perioperative/postoperative

Authors

NBNecip BecitBEBilgehan ErkutMCMünacettin Ceviz

Discussion

Loading...

Member takes

Overview

TTFM was associated with lower mortality and MI in this cohort; hypothesis-generating and requires randomized confirmation before practice change.

Structured PICO

Does intraoperative transit time flow measurement improve surgical outcomes in patients undergoing on-pump coronary artery bypass grafting?

P
Population
200 patients undergoing on-pump isolated coronary artery bypass grafting (CABG) via median sternotomy performed by the same surgical team.
I
Intervention
Intraoperative transit time flow measurement (TTFM) for assessment of graft patency during operation.
C
Comparator
No TTFM (historical control group of 100 consecutive patients before TTFM became available).
O
Outcome
Overall mortality, peri- or postoperative myocardial infarction, and intraaortic balloon pump insertion.hard clinical

The use of intraoperative transit time flow measurement during on-pump CABG allows for immediate graft revision and significantly improves surgical outcomes including mortality and perioperative MI.

Cite This Study

Becit et al. (2007) studied this question.

synapsesocial.com/papers/6a70e2db31a3df8243292202https://doi.org/10.1016/j.ejcts.2007.04.037