Answers are grounded in this paper and cite their sources.
Despite numerous studies conducted over the past few decades, the adequacy of predicting the load-bearing capacity of displacement piles and pile groups needs experimental validation. The absence of reliable test data is a leading cause of this problem. This study investigates the deformation behavior of short displacement piles and pile groups subjected to static axial loads. Most investigations into piled foundations have focused on long piles. This study gives particular attention to the evolution of the stress-strain state in the pile ground (soil mass in the pile vicinity). The experimental research on soil resistance loaded by full-scale displacement pile prototypes placed in non-cohesive artificial deposits of natural sand, common in the Baltic Sea region, was conducted in laboratory conditions to minimize uncontrolled effects. The monitoring results of the ground stresses and vertical pile displacements are presented. The pronounced effect of the installation sequence on the response of single piles acting in a pile group was estimated during the tests. Ignoring the impact can cause overstressing of the piled foundation structure and superstructure. The test results of short displacement piles and their groups were used to verify existing models for predicting ultimate pile stresses (both base and shaft) and load-bearing capacity.
No takes yet. Share an insight, caveat, or question.
Norkus et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: