Answers are grounded in this paper and cite their sources.
A study of the relative partial pressures of O₂ and the impurities CO₂, CO and H₂O upon the temperature of a platinum filament operated in oxygen at low pressure (about 10^-4 mm of mercury) has been made. The platinum filament was contained in the vacuum system of a mass spectrometer which was used as a partial pressure gauge. It was found that the partial pressure of oxygen began to fall at a filament temperature of approximately 1280^∘{}K and had dropped to 46 percent of its original value at 1740^∘{}K. This fall in the O₂ abundance was accompanied by rises in those of CO₂, CO and H₂O. Finally the effect completely disappeared. A number of considerations make it plausible that the process responsible for this effect involves the adsorption on the hot platinum filament of the oxygen molecules which on evaporation in activated form react with substances of low vapor pressure adhering to the glass envelope. The nature of the activation is most probably excitation to the metastable molecular states ¹Δ and ¹Σ. The dissociation of hydrogen by a hot tungsten filament has also been investigated and results in accord with previous work obtained.
No takes yet. Share an insight, caveat, or question.
Hagstrum et al. (1941) studied this question.