Key result
Cardiac MRI at 1.5-T proves safe with diagnostic image quality in patients with MRI-conditional pacemakers.
Why the study?
The influence of MRI-conditional cardiac pacemakers on the quality and interpretability of images acquired during 1.5-T cardiac MRI examinations required investigation.
Observational (n=12)
No
Answers are grounded in this paper and cite their sources.
Supports safe 1.5-T CMR in MRI-conditional pacemakers with acceptable quality; leaves open validation in larger prospective studies.
Purpose: The influence of MRI-conditional cardiac pacemakers on the quality and interpretability of images acquired in cardiac MRI (CMR) examinations was retrospectively investigated. Materials and methods:The subjects in this study were 12 patients (7 men and 5 women, mean age: 68.4 ± 8.7 years) with MRI-conditional cardiac pacemakers who underwent CMR examinations at our institution between July 2013 and December 2014.Two readers graded the quality of the acquired cine images, fat-suppressed black blood T2-weighted images, and late gadolinium enhancement (LGE) images.The extent of the artifacts caused by the implantable pulse generator (IPG) and the size of the artifacts caused by the leads were also measured.Results: All CMR examinations were performed safely.Image quality and interpretability were acceptable for the analysis of cardiac function and the evaluation of myocardial edema, scarring, and fibrosis, although deterioration of uniformity within the lumens due to magnetic field in homogeneity, artifacts from the leads (particularly those covering the left ventricular septal wall), and artifacts from the IPGs (particularly those covering the left ventricular anterior wall) were observed.Conclusion: CMR can be performed safely in patients with MRIconditional cardiac pacemakers, and images of sufficient quality for the assessment of cardiac anatomy and function can be obtained.
No takes yet. Share an insight, caveat, or question.
Kenichi Yokoyama (2015) conducted an observational in Atrioventricular block or sick sinus syndrome requiring cardiac pacemaker implantation, with suspected cardiac sarcoidosis or secondary cardiomyopathy (n=12). 1.5-T cardiac MRI in patients with MRI-conditional cardiac pacemakers was evaluated on Image quality and interpretability on a 4-point visual assessment scale and artifact size (mm) across SSFP cine, fat-suppressed black blood T2-weighted, and LGE images. 1.5-T cardiac MRI in 12 patients with MRI-conditional pacemakers caused no complications and yielded acceptable image quality despite larger cine IPG and lead artifacts.
Synapse has enriched 10 related papers. Consider them for comparative context: