Why the study?
Does coronary collateral flow attenuate ischemic left ventricular dysfunction during coronary occlusion in patients undergoing PCI?
Does coronary collateral flow attenuate ischemic left ventricular dysfunction during coronary occlusion in patients undergoing PCI?
Coronary collaterals exert a direct hemodynamic effect on the left ventricle, attenuating ischemic diastolic dysfunction during brief coronary occlusion.
Collateral flow may attenuate ischemic diastolic dysfunction during PCI; hypothesis-generating for collateral-targeted interventions in prospective trials.
Coronary collaterals preserve left ventricular (LV) function during coronary occlusion by reducing myocardial ischemia and may directly influence LV compliance. We aimed to re-evaluate the relationship between coronary collaterals, measured quantitatively with a pressure wire, and simultaneously recorded LV contractility from conductance catheter data during percutaneous coronary intervention (PCI) in humans. Twenty-five patients with normal LV function awaiting PCI were recruited. Pressure-derived collateral flow index (CFI(p)): CFI(p) = (P(w) - P(v))/(P(a) - P(v)) was calculated from pressure distal to coronary balloon occlusion (P(w)), central venous pressure (P(v)), and aortic pressure (P(a)). CFI(p) was compared with the changes in simultaneously recorded LV end-diastolic pressure (ΔLVEDP), end-diastolic volume, maximum rate of rise in pressure (ΔLVdP/dt(max); systolic function), and time constant of isovolumic relaxation (ΔLV τ; diastolic function), measured by a LV cavity conductance catheter. Measurements were recorded at baseline and following a 1-min coronary occlusion and were duplicated after a 30-min recovery period. There was significant LV diastolic dysfunction following coronary occlusion (ΔLVEDP: +24.5%, P < 0.0001; and ΔLV τ: +20.0%, P < 0.0001), which inversely correlated with CFI(p) (ΔLVEDP vs. CFI(p): r = -0.54, P < 0.0001; ΔLV τ vs. CFI(p): r = -0.46, P = 0.0009). Subjects with fewer collaterals had lower LVEDP at baseline (r = 0.33, P = 0.02). CFI(p) was inversely related to the coronary stenosis pressure gradient at rest (r = -0.31, P = 0.03). Collaterals exert a direct hemodynamic effect on the ventricle and attenuate ischemic LV diastolic dysfunction during coronary occlusion. Vessels with lesions of greater hemodynamic significance have better collateral supply.
No takes yet. Share an insight, caveat, or question.
Hoole et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: