We evaluated the static and dynamic polarizabilities of the 5s²0.16em0ex¹S₀ and 5s5p0.16em0ex³P₀ᵒ states of Sr using the high-precision relativistic configuration interaction combined with the all-order method. Our calculation explains the discrepancy between the recent experimental 5s²0.16em0ex¹S₀-5s5p0.16em0ex³P₀ᵒ dc Stark shift measurement Δα=247.379(7) [Middelmann et al., Phys. Rev. Lett. 109, 263004 (2012)] and the earlier theoretical result of 261(4) a.u. [Porsev and Derevianko, Phys. Rev. A 74, 020502(R) (2006)]. Our present value of 247.5 a.u. is in excellent agreement with the experimental result. We also evaluated the dynamic correction to the BBR shift with 1$%$ uncertainty; -0.1492(16) Hz. The dynamic correction to the BBR shift is unusually large in the case of Sr (7$%$) and it enters significantly into the uncertainty budget of the Sr optical lattice clock. We suggest future experiments that could further reduce the present uncertainties.
No takes yet. Share an insight, caveat, or question.
Safronova et al. (2013) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: