Why the study?
Does the HD Mesh ablator improve the rate of exit-block of all pulmonary veins compared to the Arctic Front catheter in patients with symptomatic paroxysmal atrial fibrillation?
Does the HD Mesh ablator improve the rate of exit-block of all pulmonary veins compared to the Arctic Front catheter in patients with symptomatic paroxysmal atrial fibrillation?
Continuous monitoring with an implantable loop recorder reveals a high rate (>60%) of atrial fibrillation recurrence within 12 months after a single balloon- or basket-based pulmonary vein isolation.
Answers are grounded in this paper and cite their sources.
Cryoballoon may outperform mesh ablation for PVI success in paroxysmal AF; leaves open optimal post-ablation monitoring before anticoagulation decisions.
Purpose Pulmonary vein isolation (PVI) is an established approach to treat symptomatic non-permanent atrial fibrillation (AF). Detecting AF recurrence after PVI is important, if discontinuation of oral anticoagulation after ablation is considered. Methods Patients with symptomatic paroxysmal AF were enrolled in the prospective randomized MACPAF study, comparing efficacy and safety of the HD Mesh ablator® (C.R. Bard, Lowell, USA) and the Arctic Front® (Medtronic, Minneapolis, USA) catheter. Rhythm status post PVI was closely monitored for one year using the implantable loop recorder (ILR) Reveal XT® (Medtronic Minneapolis, USA). Results The study was terminated after the first interim analysis due to the inability of the HD Mesh Ablator® to achieve the predefined primary study endpoint, an exit- block of all PVs. After a 90-day blanking period, 23 (62.2%) out of 37 study patients (median 63.0 years; 41% female) had at least one episode of AF. AF recurrence was associated with AF episodes during the blanking period (HR 5.10 [95%CI 1.21–21.4]; p=0.038), and a common left-sided PV ostium (HR 4.17 [95%CI 1.48-11.8]; p=0.039) but not with catheter type, age, gender, cardiovascular risk profile or left atrial volume. There was a trend towards AF recurrence in patients without complete PVI of all PV (p=0.095). Overall, 337 (59.4%) out of 566 ILR-detected episodes represented AF. Comparing patients with AF recurrence to those without, there was no difference in cognitive performance six months post ablation. Conclusion Using an ILR, in more than 60% of all patients with paroxysmal AF a recurrence of AF was detected within 12 months after ablation. In patients with a common PV ostium, the first generation balloon-based catheter are obviously less effective.
No takes yet. Share an insight, caveat, or question.
Schirdewan et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: