A new instrument was designed and built to record the subsonic atmospheric disturbances resulting from the explosive demolition of the German fortifications of Helgoland on April 18, 1947. Microbarometric disturbances flex the diaphragm of the microphone, altering one of two matched inductive circuits; the unbalance produces a signal voltage. This signal, the low frequency modulation of an audiofrequency carrier, is amplified and used to drive a modified Esterline-Angus graphic recorder. To provide wide dynamic range as well as high sensitivity to small signals, the amplifier has linear response to low level signals and logarithmic response to high level signals. Completely linear response is available by switching out the automatic volume-control circuit. Sensitivity may be reduced in steps to 1/5 or 1/125 to satisfy changing requirements, and at maximum sensitivity the recorder deflection is about 0.75 mm per microbar. As field equipment, the instrument system is necessarily battery operated. It is light and compact, and yet possesses high sensitivity and better stability characteristics than previous equipment of its type.