The calculation of core losses in inductive components is difficult and has not yet been entirely solved. In particular, it is impossible to predict the influence of a dc premagnetization on the losses without extensive measurements. For this paper, different materials have been tested to gain information on how core losses are influenced by a premagnetization. Measurements on molypermalloy powder, silicon steel, nanocrystalline material and ferrite cores have been performed. The Steinmetz premagnetization graph (SPG) that shows the dependency of the Steinmetz parameters ( , and ) on premagnetization is introduced. This permits the calculation of core losses under dc bias conditions. Such graphs are given for different materials and different operating temperatures. In addition, a detailed description of the test system is given, as high accuracy is crucial.
No takes yet. Share an insight, caveat, or question.
Mühlethaler et al. (2011) studied this question.