Key result
Early morning urinary albumin/creatinine ratio detects overnight microalbuminuria with 100% sensitivity and 95% specificity.
Cross-Sectional (n=265)
No
Answers are grounded in this paper and cite their sources.
In a study to monitor the acceptability of using a timed overnight urine collection to measure microalbuminuria in a large diabetic population, it was found that only 184 (69.4%) of 265 diabetics returned the urine collection to the hospital laboratory. Three proposals for an initial screening test to predict high risk microalbuminuria were analysed. Proposal I: a random urinary albumin concentration (RAC) greater than 25 micrograms/ml predicts an overnight albumin excretion rate (AER) greater than 30 micrograms/min. In 159 diabetics, the sensitivity of this screening test was 56%, specificity 81%, and predictive value 15%. Proposal II: an albumin concentration greater than 20 micrograms/ml in an early morning urine sample predicts an overnight AER greater than 30 micrograms/min. In 175 diabetics, the sensitivity of this screening test was 86%, specificity 97%, and predictive value 71%. Proposal III: an albumin/creatinine ratio (albumin mg/l creatinine mmol/l) greater than 3.5 in an early morning urine sample predicts an overnight AER greater than 30 micrograms/minute. In 171 diabetics, the sensitivity of this screening test was 100%, specificity 95%, and predictive value 64%. It is concluded that an albumin/creatinine ratio performed on an early morning urine sample brought to the diabetic clinic would be a useful initial screening test to detect an overnight AER greater than 30 micrograms/min.
No takes yet. Share an insight, caveat, or question.
Gatling et al. (1985) conducted a cross-sectional in Diabetic nephropathy / microalbuminuria (n=265). Early morning urine albumin/creatinine ratio (>3.5 mg/l per mmol/l) vs. Random urinary albumin concentration (>25 mcg/ml) and early morning albumin concentration (>20 mcg/ml) against timed overnight AER (>30 mcg/min) was evaluated on Sensitivity for predicting an overnight albumin excretion rate (AER) >30 micrograms/min. Early morning urinary albumin/creatinine ratio >3.5 detected overnight AER >/min with 100% sensitivity, 95% specificity, and 64% predictive value.
Synapse has enriched 10 related papers. Consider them for comparative context: