Answers are grounded in this paper and cite their sources.
A 10-month-old, 4 kg, Bichon Frise cross was referred for surgical stabilization of a highly comminuted L6 vertebral fracture after a road traffic accident. Nonambulatory paraparesis was present, with weak voluntary motor function in both pelvic limbs. Computed tomography (CT) of T6 to Cd1 identified a highly comminuted fracture of vertebral body and cranial endplate of L6 with severe narrowing of vertebral canal. A left-sided L6 pediculectomy was performed. The cauda equina was mildly bruised. Smaller bone fragments were removed, whereas larger bone fragments were depressed ventrally. Two 1.5-mm cortical screws were inserted into pedicles of L7 and a further two 2.0-mm screws into L5 vertebral body using the pedicle-probing technique. Following exposure of underlying cancellous bone, a smartphone digital goniometer, held by a nonsterile assistant, was used to guide advancement of a blunted Kirschner wire acting as a probe according to preoperative CT-determined safe angles. Postoperative CT identified excellent vertebral column alignment with improvement in spinal cord compression and optimal placement of implants at L5 and L7 (grade 1 modified Zdichavsky). Repeat CT at 3 months postoperatively identified well-seated implants. This report highlights that use of a smartphone goniometer may be a useful adjunct to the freehand pedicle-probing technique to guide correct trajectory of the probe and may also have application in other regions of the spine.
No takes yet. Share an insight, caveat, or question.
Mullins et al. (2024) studied this question.