Key result
CT perfusion ischemic core estimates correlate strongly with final infarct volume after recanalization.
Observational (n=52)
No
Answers are grounded in this paper and cite their sources.
Observational study shows varying CT perfusion thresholds alter ischemic core and penumbra volumes in acute ischemic stroke, highlighting the need for standardized analysis.
PURPOSE: This single-center study compared three threshold settings for automated analysis of the ischemic core (IC) and penumbral volumes using computed tomographic perfusion, and their accuracy for predicting final infarct volume (FIV) in patients with anterior circulation acute ischemic stroke (AIS). METHODS: Fifty-two consecutive AIS patients undergoing mechanical thrombectomy (November 2015-March 2018) were included. Perfusion images were retrospectively analyzed using a single CT Neuro perfusion application (syngo.via 4.1, Siemens Healthcare GmbH). Three threshold values (S1-S3) were derived from another commercial package (RAPID; iSchema View) (S1), up-to-date syngo.via default values (S2), and adapted values for syngo.via from a reference study (S3). The results were compared with FIV determined by non-contrast CT. RESULTS: The median IC volume (mL) was 24.6 (interquartile range: 13.7-58.1) with S1 and 30.1 (20.1-53.1) with S2/S3. After removing the contralateral hemisphere from the analysis, the median IC volume decreased by 1.33(0-3.14) with S1 versus 9.13 (6.24-14.82) with S2/S3. The median penumbral volume (mL) was 74.52 (49.64-131.91), 77.86 (46.56-99.23), and 173.23 (125.86-200.64) for S1, S2, and S3, respectively. Limiting analysis to the affected hemisphere, the penumbral volume decreased by 1.6 (0.13-9.02), 19.29 (12.59-26.52), and 58.33 mL (45.53-74.84) for S1, S2, and S3, respectively. The correlation between IC and FIV was highest in patients with successful recanalization (n = 34, r = 0.784 for S1; r = 0.797 for S2/S3). CONCLUSION: Optimizing thresholds significantly improves the accuracy of estimated IC and penumbral volumes. Current recommended values produce diversified results. International guidelines based on larger multicenter studies should be established to support the standardization of volumetric analysis in clinical decision-making.
No takes yet. Share an insight, caveat, or question.
Karhi et al. (2021) conducted an observational in Anterior circulation acute ischemic stroke (n=52). CT perfusion automated analysis threshold settings (S1, S2, S3) vs. Final infarct volume determined by non-contrast CT was evaluated on Estimated ischemic core and penumbral volumes and correlation with final infarct volume (r = 0.784 (S1); r = 0.797 (S2/S3)). CT perfusion threshold settings S1 and S2/S3 yielded median ischemic core volumes of 24.6 mL and 30.1 mL, correlating strongly with final infarct volume after recanalization.
Synapse has enriched 10 related papers. Consider them for comparative context: