Previous experimental work has established that the near perfection of some selected iron whiskers brings the axial magnetic field required to nucleate the reversal of magnetization close to the theoretical coercive force limit of 2K/Ms (560 oe at 20°C). [R. W. De Blois and C. P. Bean, J. Appl. Phys. 30, 225S (1959)]. Further experiments now show an approximately constant shift of the nucleation-field contour along an iron whisker with change in temperature, increases in nucleation field of several hundred oersteds along the lengths and at the tips of several iron whiskers following electropolishing, and a correlation between observed microscopic surface imperfections and regions of nucleation-field minima. These results support current ideas that abrupt surface contour variations are primarily responsible for reducing the observed nucleation fields for iron whiskers to below the ideal value.
No takes yet. Share an insight, caveat, or question.
R. W. De Blois (1961) studied this question.