Answers are grounded in this paper and cite their sources.
Two structures, a switched-capacitor (SC)-based boost converter and a two-level inverter, are connected in cascade. The dc multilevel voltage of the first stage becomes the input voltage of the classical inverter, resulting in a staircase waveform for the inverter output voltage. Such a multilevel waveform is close to a sinusoid; its harmonics content can be reduced by multiplying the stage number of the SC converter. The output low-pass filter, customary after a two-level inverter, becomes obsolete, resulting in a small size of the system, as the SC circuit can be miniaturized. Both stages are operated at a high switching frequency, resulting in a high-frequency inverter output, as required by some industrial applications. A Fourier analysis of the output waveform is performed. The design is optimized with reference to the nominal duty-cycle for obtaining the minimum total harmonic distortion. Simulations and experiments on two prototypes, one with a five-level output and one with a seven-level output, confirm the theoretical analysis.
No takes yet. Share an insight, caveat, or question.
Axelrod et al. (2005) studied this question.