Today's voltage regulator (VR) for the microprocessor requires a current loop to achieve adaptive voltage positioning and phase current sharing. A fundamental limitation, current loop sample hold effect, limits the control bandwidth to be pushed beyond 1/6 of the switching frequency. This paper reveals the limitation of the control bandwidth of a two-phase buck converter using peak current control scheme. The limitation can be overcome by coupling the two output inductors. A new small signal model is proposed to study the sample hold effect in coupled-inductor implementations. The relationship between the coupling coefficient and the sample hold effect is then discussed. Based on these understandings, a strongly coupled two-phase buck converter has double the bandwidth of the noncoupled VR; and this is experimentally verified
No takes yet. Share an insight, caveat, or question.
Xu et al. (2007) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: