Answers are grounded in this paper and cite their sources.
A fully integrated toroidal inductor is realized on a silicon wafer by using a multilevel metallization technique to fabricate a wrapped coil wound around a micromachined bar of high-permeability magnetic material. In particular, efforts are made to minimize the coil resistance by using thick conductor lines and electroplated vias. In this structure, a 30 /spl mu/m thick nickel-iron permalloy magnetic core is wrapped with 40 /spl mu/m thick multilevel copper conductor lines, constructing a conventional toroidal inductor in planar shape. A closed magnetic circuit (i.e., toroidal) in this inductive component is adopted, where magnetic core bar and wrapped conductor lines are tightly interlinked, so that leakage flux and electromagnetic interference are minimized. For an inductor size of 4 mm/spl times/1 mm/spl times/130 /spl mu/m thickness having 33 turns of multilevel coils, the achieved inductance is approximately 0.4-0.1 /spl mu/H at 1 kHz-1 MHz, corresponding to a core permeability of approximately 800. The measured dc resistance of the conductor lines is approximately 0.3 /spl Omega/. Since this inductive component shows favorable magnetic characteristics as well as electrical properties, it is potentially very useful as a basic inductive component in applications for magnetic microsensors, microactuators, and micromagnetic power devices such as a dc/dc converter.>
No takes yet. Share an insight, caveat, or question.
Ahn et al. (1994) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: