Answers are grounded in this paper and cite their sources.
To date, the design of unstiffened steel shear walls has three issues that make them expensive to employ: 1) large columns resulting from the shear wall applying lateral loads to the columns; 2) expensive field-welded moment connections; 3) buckling of the steel plate under service earthquakes and winds. A new, innovative system, called the high-performance steel shear wall system, is developed and proposed by the authors to solve these problems. In this system: 1) the steel plate shear wall is not connected to the columns, therefore, the columns do not experience large lateral forces; 2) the beam-to-column connections consist of an innovative and cost-effective connection developed by the authors, referred to as a gusset plate moment connection; 3) the thickness of the plate is independent of the column size, enabling the use of thicker plates to prevent buckling of the steel plate under service loads.
No takes yet. Share an insight, caveat, or question.
Asl et al. (2016) studied this question.
Synapse has enriched 9 related papers. Consider them for comparative context: