Answers are grounded in this paper and cite their sources.
Polyethylenes are rated for relative a-c dielectric strength by their treeing tendency at a "standard defect," i. e., a needle point embedded in a block of polyethylene and stressed versus a remote ground. The "1-hour characteristic voltage," defined as that causing half a group of samples to develop trees in one hour, has been raised by additives from 19 kv (kilovolts) (original) to as high as 80 kv. Results correlate with a-c step and life tests on wire.
No takes yet. Share an insight, caveat, or question.
Kitchin et al. (1962) studied this question.