Answers are grounded in this paper and cite their sources.
Formative time-lags of spark breakdown have been measured for air in uniform fields with static applied voltages up to 63 kV; and the very long time lags (greater than 10 -4 s) predicted by theory for such conditions have been recorded. Time-lag data have also been obtained for air in uniform fields with impulse spark voltages up to 150 kV for standard impulse waveforms, and also for lower voltages with non-standard impulse waveforms. For the latter condition the data indicate an impulse ratio of the order of 1.01. Comparative data for sphere gaps are included.
No takes yet. Share an insight, caveat, or question.
Aked et al. (1955) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: