Answers are grounded in this paper and cite their sources.
Atomic-scale adhesion phenomena between KBr tip and sample were studied by dynamic force spectroscopy with a small amplitude of down to 2850.28em0expm at room temperature. The high-resonance frequency of the second flexural mode of a silicon cantilever (≈10.28em0exMHz) suppresses an apparent dissipation energy caused by undesirable mechanical couplings in between the cantilever and the dither piezo actuator. Further, the Joule heating dissipation contribution and the noise-equivalent dissipation energy were reduced by setting a smaller amplitude. Usage of a high resonance frequency and a smaller amplitude enables us to perform highly sensitive measurements of the atomic-scale adhesion and the tip-instability-related energy dissipation. Tip changes, caused by tip-sample interactions and thermal energy, resulted in three different dissipation energy levels (ΔEₜₛ≈250.28em0exmeV/cycle). This infrequent change of the tip apex condition often prevents a stable imaging with small amplitude. Our systematic measurement shows that the atomic adhesion is caused mainly in the tip itself, and a sharper and softer tip induced a larger energy dissipation.
No takes yet. Share an insight, caveat, or question.
Kawai et al. (2012) studied this question.