Experiments have been carried out to investigate the breakdown mechanism in Perspex over a temperature range from 20 to 160°C, using impulse voltages of widely differing rise times. The electric strength was found to be sensitive to voltage rise time, reaching a maximum as the rise time is increased, but falling again at longer rise times towards the dc value. The results are discussed in terms of a model in which space charges accumulate at the electrodes, positive charges at the anode, and negative charges at the cathode.
No takes yet. Share an insight, caveat, or question.
D.B. Watson (1973) studied this question.