Key points are not available for this paper at this time.
Design
Editorial
Answers are grounded in this paper and cite their sources.
This editorial highlights the potential of the ventricular gradient angle derived from standard ECG as a promising marker for sudden cardiac death risk stratification to improve patient selection for primary ICD prophylaxis.
This editorial refers to ‘QRS-T morphology measured from exercise electrocardiogram as a predictor of cardiac mortality’ by T. Kenttä et al., on page 701. The benefits of the prophylactic clinical use of implantable cardioverter-defibrillators (ICD) have been documented beyond any reasonable doubt by a multitude of prospective clinical trials.1–3 This does not mean that the present ICDs are without limitations and that further technical advances are not needed. Among other challenges, inappropriate shocks, frequent in some patients, not only limit the broader use of the devices but also pose a risk on their own. Also, attempts at initiating ICD prophylaxis shortly after acute myocardial infarction have so far been unsuccessful.4,5 Whether this relates to the implantation procedures, including test shocks, or whether the recently infarcted myocardium is particularly vulnerable to appropriate shocks and/or to other impacts of ICD implants is unknown. Still, the restriction of ICD implantation in patients with ischaemic heart disease to the chronic post-infarction stages is regrettable. High rates of the sudden cardiac deaths, potentially avoidable by ICD interventions, appear shortly after the infarction.6 These are examples of difficulties in ICD prophylaxis that need to be solved by a combination of further technological and clinical advances. Nevertheless, these challenges are not the major problem of ICD prophylaxis. The major unmet clinical need concerns the selection of candidates for primary ICD prevention. It is well known that the reduced left ventricular ejection fraction (LVEF) is not only the present goal standard of risk stratification for these purposes but it is also the only selection criterion that has gained the acceptance by both the clinical community and healthcare providers. Additional selection criteria, such as the prolonged QRS duration on standard resting electrocardiogram (ECG), that have also been occasionally imposed, are mostly seen as cost-cutting measures reflecting the difficult economics of healthcare. At the same time, selection of candidates for ICD implantation by reduced LVEF is neither specific nor sensitive.6,7 Irrespective of which dichotomy limit for LVEF is used, the majority of patients with compromised ventricular performance do not suffer from arrhythmic complications and thus never utilize prophylactic devices. At the same time, the majority of arrhythmic episodes potentially treatable by ICDs occur in patients with preserved LVEF. Hence on the one hand, the LVEF-based selection of ICD candidates makes the prophylaxis expensive and wasteful while on the other hand, the majority of patients who might benefit from ICD prophylaxis are left to die because we cannot identify them accurately. This problem has been well recognized by the research community interested in cardiac risk stratification. A number of risk stratifiers have been reported capable of solving the dilemma of LVEF-based risk stratification to a variable degree. A large part of these suggestions concentrate on the assessment of cardiac autonomic status. Consistent with experimental observations that the autonomic system offers a natural defense against cardiac arrhythmias,8 risk markers derived from autonomic indices appear fairly promising. In cohort studies of large collections of data from survivals of acute myocardial infarction, it has been reported that among patients with preserved LVEF, autonomic markers can identify a high-risk subgroup with the same incidence of cardiac and sudden cardiac death as in patients with reduced LVEF.8 Still, prospective confirmation of these findings is missing, likely because of practical problems of deriving the autonomic markers from long-term ECGs.9 It is thus becoming obvious that any successful risk stratifier that would be clinically useful to complement if not replace reduced LVEF must be obtainable easily without a substantial healthcare burden. Clearly, to design such stratifiers is not easy. Hence, a consensus is emerging that the most promising way forward is in a multivariate approach with stepwise risk assessment. In such a strategy, very simple tests are needed to identify large proportions of the truly low-risk patients in whom further risk assessment and thus possibly burdensome testing can be avoided. While negative findings of T-wave alternans have been reported to offer such a selection of low-risk patients,10 much simpler tests would be of a greater practical value. Considering this need, it is very pleasing to note that strong-risk stratifiers can be derived from standard resting ECG. The most promising of these appears to be the angle of the ventricular gradient (VG), that is, the three-dimensional angle between the principal orientations of the QRS complex and of the T-wave. Since the seminal observation that the VG angle is a risk predictor among post-infarction patients,11 the power of this risk predictor has been repeatedly confirmed in a number of investigations researching both cardiac patients and general populations.12–17 The mechanisms linking an increased VG angle to an increased risk so strongly are unknown. Actually, considering the potential practical importance of this risk marker, little is known about its physiologic correlates and influences. Superficially, some properties of the VG angle resemble those of QT interval duration. Similar to the QT interval, VG angle is dependent on the heart rate18 and shows a highly statistically significant difference between healthy female and male subjects.19 Moreover, the relationship to heart rate shows large differences between different subjects while it seems to be stable within each individual.20 However, it is not directly linked to the QT interval duration. Subjects who show similar QT/RR patterns may have remarkably different patterns between heart rates and the VG angle. Also, while QT interval duration adapts to the changes in heart rate slowly and thus exhibits substantial QT/RR hysteresis, the adaptation of the VG angle appears much faster with little or perhaps no hysteresis.21 Other important properties of VG angle are unknown. For instance, we do not know whether it is under any autonomic influence independent of the heart rate dependency, how it is changed by ischaemia, whether it is changed by drugs and in which way, how drug-induced changes relate to the modification of the QT interval by the same compounds, whether the sex difference found in adults (and independent of sex difference in heart rate) develops around puberty when the sex differences in QTc appear, and so on. All these gaps in our knowledge should be noted by the research community. Different studies that previously researched VG also used different technical tools for the measurement.22,23 While the principal orientation of the T-wave loop is usually easy to define, the definition of the principal orientation of the QRS complex may pose severe problems even in healthy normal ECGs (Figure 1). Hence, standardization of the VG angle measurement is needed so that universally comparable normality limits and risk stratification dichotomies can be established. The figure shows four different projections of the three-dimensional representation of the same short-term electrocardiogram of a normal healthy subject (four cardiac cycles are shown). Note that while the three-dimensional orientation of the T-wave loop (the small narrow loop) is easy to define, the orientation of the QRS complex loop (the large broad loop) in the system of the three coordinates is more problematic. Very little is also known about the beat-to-beat stability of the VG angle, including the influence of the measurement technology on this stability and reproducibility. Since T-wave morphology in standard ECGs is influenced by respiration, it is not clear whether the measurements at different cardiac cycles are influenced by variable technical artefacts or whether any measured beat-to-beat changes reflect a true physiologic cycle-to-cycle variability. From studies of T-wave morphologies, we know that the beat-to-beat variability is of importance regardless of whether it is a cyclic variability of the alternans type or whether it is an erratic variability indicative of unstable and heterogeneous repolarisation.24 In terms of the VG angle, this is all complicated by its heart rate dependence. While the QT interval is practically stable during short episodes of RR interval changes, e.g. due to respiratory arrhythmia, the lack of hysteresis in heart rate adaptation is likely to make the VG angle naturally more variable. The measurements of VG angle variability thus pose a challenging problem. It is therefore pleasing that in this issue of the Journal, Kenttä et al.25 present a seminal report on the variability of the VG angle and on the links of this variability to cardiac risk. Kenttä et al. have not studied a true beat-to-beat variability since their data originated from representative ECG waveforms derived from 10 consecutive beats at any given measurement instance. Nevertheless, their observation on the loss of the clear heart rate dependency in high-risk patients is of interest. Reasonably, one can speculate that if the investigations reflected the true beat-to-beat variability, the results might have been even more striking. Even in the report by Kenttä et al., there are several unresolved questions. For instance, it is not obvious whether the variability is contributed more by the absolute changes in the T-wave orientation or whether the QRS complex loops are also variable in the high-risk patients. A part of the measurement technology used by Kenttä et al. was initially developed to provide a stable expression of QRS complex spatial orientation but it does not necessarily correspond to the other technologies for the measurement of the gradient. Indeed, the two measurement methods used by Kenttä et al. led to different cut-off values. The mechanisms suggested from the observations by Kenttä et al. can be complemented by a number of other possibilities including the heterogeneity of depolarization and repolarization processes independent of the underlying heart rate and autonomic changes. While Kenttä et al. present their findings mainly in terms of risk stratification, the physiologic aspects of the study should not be neglected. Irrespective of the distinction of the different levels of cardiac risk, studies of this kind are needed for us to understand the detailed properties of VG and of its dynamicity both under normal and pathological conditions. Increased knowledge of that kind is bound to improve our ability of using the VG angle effectively in future studies of prospective risk assessment and verification of prophylactic interventions. Conflict of interest: none declared.
No takes yet. Share an insight, caveat, or question.
Marek Malík (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: