This is the authors' abstract. We don't add key points for this paper.
A full-scale blast test was conducted on eight masonry walls reinforced with two and four layers of carbon fibers and two types of polymer matrices. The walls were then subjected to a 0.45-kg pentolite booster suspended from the ceiling of a test structure. The pressure-time history caused by the blast and the resulting displacement response were measured during the test. This paper presents a summary of the test program and the corresponding results from a nonlinear single degree of freedom analysis. The results provide a basis for determining effective means of retrofitting existing masonry walls and designing new structures to withstand blast loads. The paper also outlines a fiber-reinforced polymer retrofit design procedure for walls subjected to blast loading.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Urgessa et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: