Answers are grounded in this paper and cite their sources.
Average-value models (AVMs) of voltage-source converters (VSCs) are widely used as numerically efficient alternatives to their discrete switching models in electromagnetic transient (EMT) simulations. Recently, a so-called directly-interfaced AVM (DI-AVM) has been developed for VSCs, permitting large simulation time steps favorable for system-level offline and/or real-time studies. Although enabling large step sizes, the conductance/resistance matrix of the DI-AVM is time-varying and needs to be calculated at every simulation time step, which requires additional computational resources. This paper proposes a constant-parameter DI-AVM (CP-DI-AVM) for more efficient simulations of VSC-based power-electronic systems that does not require re-calculation of the network conductance matrix in EMT simulators. This is achieved by using a numerical approximation that only slightly reduces the solution accuracy. The performance of the proposed CP-DI-AVM is demonstrated on a large-scale VSC-based energy conversion system implemented in PSCAD/EMTDC. The proposed CP-DI-AVM is shown to have numerical advantages over the prior DI-AVM and the conventional AVMs of VSCs.
No takes yet. Share an insight, caveat, or question.
Ebrahimi et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: