Why the study?
Do automated immunoturbidometric D-dimer methods provide comparable diagnostic sensitivity and NPV to established methods in symptomatic patients suspected of DVT?
Do automated immunoturbidometric D-dimer methods provide comparable diagnostic sensitivity and NPV to established methods in symptomatic patients suspected of DVT?
Automated immunoturbidometric D-dimer methods demonstrate high sensitivity and NPV comparable to established ELISA methods, supporting their use in the diagnostic algorithm for suspected DVT.
Rapid D-dimer sensitivities vary in suspected DVT; leaves open reliable rule-out performance pending prospective validation.
We evaluated six D-dimer methods to determine their sensitivity, specificity, and negative predictive values (NPV) in symptomatic patients suspected of deep vein thrombosis (DVT). In patients suspected of DVT a whole blood D-dimer test (SimpliRED, Agen) was performed, and then tested using enzyme-linked immunosorbent assay (VIDAS D-Dimer, BioMerieux; Asserachrome D-Di, Stago International; Dimertest Gold, Agen) and automated immunoturbidometric methods (Advanced D-Dimer, Dade Behring; MiniQuant, Biopool). Each D-dimer method was independently compared with radiographic results to determine sensitivity and NPV. There were 151 patients enrolled in the study. Thirty-five (23.2%) patients had a positive Doppler ultrasound, with 26 proximal, eight distal, and one patient with both proximal and distal thrombus. Two patients (1.3%) had inconclusive studies and were excluded from the analyses. For all patients, the sensitivities for the rapid D-dimer methods were: SimpliRED, 82.3% [95% confidence interval (CI), 80.3-84.3%]; VIDAS D-Dimer, 91.4% (95% CI, 89.9-92.9%); MiniQuant D-Dimer, 96.3% (95% CI, 95.1-97.5%); and Advanced D-Dimer, 97.1% (95% CI, 96.3-97.9%). The sensitivity improved for SimpliRED (86.4%; 95% CI, 83.3-89.4%), VIDAS D-Dimer (95.5%; 95% CI, 85.0-100%), MiniQuant D-Dimer (100%; 95% CI, 96.9-100%) and Advanced D-Dimer (100%; 95% CI, 98.9-100%) in the inpatient population. The automated immunoturbidometric methods, the MiniQuant D-Dimer and Advanced D-Dimer, demonstrated comparable sensitivities and NPV with the VIDAS D-Dimer method in symptomatic patients suspected of DVT, which would suggest that these newer D-dimer methods could be used as part of the diagnostic algorithm for patients suspected of DVT.
No takes yet. Share an insight, caveat, or question.
Gosselin et al. (2003) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: