Why the study?
Following demonstrated reliability of the Hand Test System glove at baseline, the study aimed to assess the functionality of single fingers in rheumatoid arthritis hands at follow-up.
Does the engineered Hand Test System (HTS) glove correlate with traditional clinimetric indexes in assessing finger function in rheumatoid arthritis patients over time?
Does the engineered Hand Test System (HTS) glove correlate with traditional clinimetric indexes in assessing finger function in rheumatoid arthritis patients over time?
The HTS glove provides an objective measurement of single finger function and movement speed in rheumatoid arthritis, complementing traditional clinimetric indexes.
Answers are grounded in this paper and cite their sources.
HTS glove may enable serial single-finger monitoring in RA; leaves open clinical adoption pending prospective validation.
The engineered Hand Test System (HTS) glove has shown high reliability in assessing the baseline functional status of rheumatoid arthritis (RA) hand. Starting from this achievement, the aim of the present observational prospective study was to assess the functionality of the single fingers of rheumatoid hand at follow-up. Eighty RA patients performed HTS glove tests at baseline and among these fifty-six patients were re-tested after 7 months. The HTS glove parameters [Touch Duration (TD), Movement Rate (MR), Inter Tapping Interval (ITI)] were correlated with disease activity and disability clinimetric indexes [Disease Activity Score 28 joint count-C-reactive protein (DAS28-CRP), Clinical Disease Activity Index (CDAI), Simplified Disease Activity Index (SDAI), Health Assessment Questionnaire-Disability Index (HAQ-DI), grip strength, visual analogue scale of pain (VAS), patient global assessment (PGA)], and with laboratory values. HTS glove parameters (TD, ITI, and MR) showed statistically significant correlations with clinimetric and clinical indexes at both time points (p < 0.05). During follow-up, a statistically significant variation of all HTS glove parameters for the fingers that have performed both the worst or best HTS test at baseline was detected (p < 0.05), while the mean HTS glove parameter values by considering all fingers did not show a statistically significant variation over time, as well as the traditional clinimetric indexes. Besides the objective role in assessing the RA hand function by integrating the traditional clinimetric indexes, the HTS glove seems a useful tool for evaluating worst or best finger function during time by measuring the movement speed.
No takes yet. Share an insight, caveat, or question.
Sulli et al. (2023) studied this question.