Answers are grounded in this paper and cite their sources.
Evaluates the impact of human occupancy on indoor air quality in classrooms, suggesting improved ventilation is needed.
This study evaluates how human presence influences classroom air quality using an edge-intelligent, low-cost monitoring system (AQMS) that senses multiple pollutants and quantifies occupancy with an on-board camera and custom object-detection model. Over seven days in a laboratory, we varied air-conditioning and ventilation settings while the AQMS logged pollutant levels every minute. Spearman rank-order analysis showed strong positive correlations between occupancy and CO2, total VOCs, and gas-sensor resistance, but no significant link with CO, NH3, or NO2. Particulate matter (PM2.5, PM10) briefly fell as occupancy rose, yet this trend vanished when air-conditioning was active, indicating its filtration effect. Rooms without air-conditioning but with adequate ventilation maintained lower CO2 and VOC levels. PM findings were inconclusive because of concurrent inhalation effects. All occupancy data were privacy-preserving—images were processed on device and never stored. Although demonstrated in a single room, the architecture is inherently scalable, and a multi-room urban–rural deployment is underway.