The steady flow characteristics around a swing-type valve plate installed in a rectangular duct are studied theoretically and experimentally in order to determine the fluid force acting on a swing-type check valve and the side-gap-leakage effects. The results show that the side-gap leakage has dominant influence upon the fluid force characteristics, which can be well predicted by a small modification of the conventional two-dimensional potential flow theory. For the case of a large side gap, the pressure over the valve plate becomes nearly uniform and is equal to the upstream one. And that the fluid force is expressed as a function of only the velocity ratio of the jet to the upstream, if the side-gap-leakage is less than the mainflow volume. It is pointed out that the separation zone at the back of a valve plate is recovered very rapidly due to momentum transfer effects of side-gap-leakage, and that the outlet flow from a valve plate is not contracted with its width nearly equal to the valve opening one. The experimental formulae of moment coefficient are also presented.
No takes yet. Share an insight, caveat, or question.
Kurokawa et al. (1986) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: