Answers are grounded in this paper and cite their sources.
We explore the effect of pre-stretch and application of mechanical loads on a soft polydimethylsiloxane (PDMS) elastomer to obtain high linear strain freestanding dielectric elastomer actuators. It is shown that when the mechanical loads are properly applied, large linear actuation strains of 120% and work density of 0.5 J cm−3 can be obtained due to a transition from pure-biaxial to pure-uniaxial actuation conditions. Furthermore, we demonstrate that when coupled with single wall carbon nanotube (SWNT) compliant electrodes, fault-tolerance is introduced via self-clearing leading to significantly improved operational reliability. Cycling actuation tests reveal that even after more than 30 self-cleared electrical breakdown events the actuators maintain a high level of performance. Driven at moderate electric fields, the actuators display relatively high linear actuation strain (25%) without degradation of the electromechanical performance even after 85 000 cycles.
No takes yet. Share an insight, caveat, or question.
Stoyanov et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: