Does radiofrequency catheter modification of the sinus node restore normal rhythm in a patient with persistent inappropriate sinus tachycardia?
Does radiofrequency catheter modification of the sinus node restore normal rhythm in a patient with persistent inappropriate sinus tachycardia?
Radiofrequency ablation of the sinus node may be an effective treatment for persistent inappropriate sinus tachycardia.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for sinus node ablation in inappropriate sinus tachycardia; larger studies needed before clinical adoption.
Radiofrequency catheter modification of the sinus node for persistent inappropriate sinus tachycardia has not been previously reported. This article describes a patient in whom radiofrequency current was used to ablate an incessant automatic tachycardia focus mapped to the region of the sinus node, where a discrete multicomponent electrogram demonstrating earliest atrial activation was recorded. A transient junctional rhythm developed immediately after ablation, with rapid subsequent emergence of a stable rhythm having normal sinus nodal characteristics.