Aim: This research investigated the distinct irrigation protocols: 17% ethylenediaminetetraacetic acid (EDTA), QMix, 40% citric acid on the mechanical properties of root dentin, particularly, nanohardness, and flexural strength.Materials and methods: Forty sound single-rooted mandibular premolars extracted for orthodontic or periodontic reasons were selected.The canals were mechanically prepared using ProTaper Next rotary instruments.Each root was longitudinally bifurcated into two halves; one was designated for nanohardness measurement, while the other was processed into a dentin bar for flexural strength testing.Both sample sets (n = 10 per group) were then randomly allocated into four study groups.In group I: 5 mL of EDTA was used for 2 minutes and then flushed with saline.Similarly, groups II, III, and IV used QMix, 40% citric acid, and normal saline (control).The nanohardness was measured using a nanoindenter with a Berkovich diamond tip.Flexural strength was evaluated via a three-point bending test.The obtained data were statistically analyzed using a one-way analysis of variance (ANOVA) test and a post hoc multiple comparison test, with a significance level set at 5%.Results: The control group exhibited the highest mean nanohardness at 0.49 ± 0.06 GPa, whereas the 17% EDTA group showed the lowest mean at 0.28 ± 0.07 GPa, representing a statistically significant difference (p < 0.05).A similar trend was observed for flexural strength, with the control group reaching 108.5 ± 23.8 MPa and the 17% EDTA group exhibiting the lowest strength at 55.9 ± 23.6 MPa.Overall, 17% EDTA significantly reduced both nanohardness and flexural strength compared with all other study groups (p < 0.05). Conclusion:The mechanical properties of dentin were significantly influenced by the choice of irrigant, with both nanohardness and flexural strength following a descending order of normal saline > QMix > citric acid > EDTA.These findings indicate that while all tested chelating agents impacted the tooth's structural integrity, 17% EDTA exhibited the most deleterious effect on the mechanical properties of root dentin compared with the other groups.Clinical significance: Choosing an appropriate irrigant is vital for preserving the tooth's structural integrity.Since 17% EDTA significantly reduces nanohardness and flexural strength, using alternatives like QMix or citric acid may better maintain the mechanical properties of dentin and reduce the risk of posttreatment root fractures.
No takes yet. Share an insight, caveat, or question.
Alharbi et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: