Does postdilatation reduce paravalvular regurgitation in patients undergoing balloon-expandable TAVR?
Does postdilatation reduce paravalvular regurgitation in patients undergoing balloon-expandable TAVR?
Postdilatation is effective at reducing paravalvular regurgitation in patients with greater than mild PVR after balloon-expandable TAVR without significantly increasing major aortic injury or pacemaker rates.
Answers are grounded in this paper and cite their sources.
Supports consideration of postdilatation for greater-than-mild PVR after balloon-expandable TAVR; leaves open confirmation in randomized trials.
BACKGROUND: Paravalvular regurgitation (PVR) is common after transcatheter aortic valve replacement (TAVR) and may be associated with adverse outcomes. Postdilatation (PD) has been proposed to treat PVR without being formally studied. We performed a study to evaluate the safety and efficacy of PD after balloon expandable TAVR. METHODS AND RESULTS: Consecutive cases of TAVR were reviewed for clinical outcomes. Procedural transesophageal echocardiography imaging was reviewed for a subgroup of consecutive patients. PVR areas seen on a short-axis view were measured immediately after deployment, after PD, and at the completion of the study. Stent dimensions measured using angiography and the Paieon's C-THV system pre- and post-PD were compared. Between May 2007 and November 2011, 259 patients underwent TAVR at our institution. PD was performed in 106 patients (41%). These patients had larger annulus, lower cover-index; more often had transfemoral access and implantation of a 26 mm valve. There was a nonsignificant greater rate of cerebrovascular events in PD patients. There was no significant difference in major aortic injury and permanent pacemaker implantation rates between groups. TTE studies were reviewed in 58 patients (35 with PD and 23 without PD). PD patients had larger PVR areas immediately after deployment (40.3±17.1 versus 15.4±14.2 mm(2); P<0.0001). There was significant reduction in PVR area attributable to PD (21.7±9.3 mm(2); P<0.0001). Spontaneous regression of PVR was seen in both groups. PD increased stent dimensions. CONCLUSIONS: This study demonstrates the efficacy of PD at reducing PVR in patients with greater than mild PVR after balloon-expandable TAVR.
No takes yet. Share an insight, caveat, or question.
Daneault et al. (2013) studied this question.