Why the study?
The study was conducted to develop a high temporal resolution phase-contrast pulse sequence for evaluating diastolic filling patterns and evaluate it against transthoracic echocardiography.
Does high temporal resolution phase-contrast MRI accurately measure diastolic filling patterns compared to transthoracic echocardiography in patients?
Does high temporal resolution phase-contrast MRI accurately measure diastolic filling patterns compared to transthoracic echocardiography in patients?
A novel high temporal resolution phase-contrast MRI sequence enables accurate assessment of myocardial velocities and early-to-late filling ratios comparable to echocardiography during a single breath-hold.
High temporal resolution phase-contrast MRI feasible for diastolic assessment in humans; leaves open validation and clinical role versus echocardiography.
Purpose To develop a high temporal resolution phase‐contrast pulse sequence for evaluation of diastolic filling patterns, and to evaluate it in comparison to transthoracic echocardiography. Methods A phase‐contrast velocity‐encoded gradient‐echo pulse sequence was implemented with a sector‐wise golden‐angle radial ordering. Acquisitions were optimized for myocardial tissue (TE/TR: 4.4/6.8 ms, flip angle: 8º, velocity encoding: 30 cm/s) and transmitral flow (TE/TR: 4.0/6.6 ms, flip angle: 20º, velocity encoding: 150 cm/s). Shared velocity encoding was combined with a sliding‐window reconstruction that enabled up to 250 frames per cardiac cycle. Transmitral and myocardial velocities were measured in 35 patients. Echocardiographic velocities were obtained with pulsed‐wave Doppler using standard methods. Results Myocardial velocity showed a low difference and good correlation between MRI and Doppler (mean ± 95% limits of agreement 0.9 ± 3.7 cm/s, R 2 = 0.63). Transmitral velocity was underestimated by MRI ( P < .05) with a difference of −11 ± 28 cm/s (R 2 = 0.45). The early‐to‐late ratio correlated well (R 2 = 0.66) with a minimal difference (0.03 ± 0.6). Analysis of interobserver and intra‐observer variability showed excellent agreement for all measurements. Conclusions The proposed method enables the acquisition of phase‐contrast images during a single breath‐hold with a sufficiently high temporal resolution to match transthoracic echocardiography, which opens the possibility for many clinically relevant variables to be assessed by MRI.
No takes yet. Share an insight, caveat, or question.
Fyrdahl et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: